Difficulty
Temperature sensor for all AWR/ABR units and select NWC units.
Tools Need:
- Phillips screwdriver
- scissors/wire cutters
- small zip ties
- tape (optional)
The following unit used for this demonstration is a NWC046BS00.
- Open the door of your unit and remove all the shelves/racks
-
Unscrew the zone separation panel then slide it out.
- With the divider pulled, disconnect this wire connection.
- Remove the temperature sensor cages to free up the temperature sensors from the other side of the back panel.
- Remove these 6 screws to reveal the back side of the panel
- Unscrew the bundle of wires from the back wall.
- Remove the top sensor from the panel and disconnect from the bundle of wires.
- For the bottom temp sensor, you will need to snip this zip tie to disconnect the connector.
- Now, replace the bottom temperature sensor and zip tie the blue wire bundle.
- Secure each temperature sensor to the panel wall and fasten the cages removed from step 4.
- Now, you will need to tuck the blue bundle of wires in the crevice to the right of the evaporator pipes. Use tape if necessary. Then screw the back panel back on and insert the zone divider.
ONLINE SUPPORT
Send us a message through our live chat messenger at Newair
Send us an email at support@newair.com(We will respond to you within 24 hours during our normal business hours: M-F from 8-4pm PST)
Call our support team: 1 (855) 963-9247