Part Needed: AW-FAN-6
Difficulty
External condenser fan for various beverage and wine coolers. Applies to all AWR and ABR units.
Tools Needed:
- Phillips screwdriver
The following unit used for this demonstration is an ABR-1770.
-
Carefully place unit on its front face. Use cardboard or a rug to provide a soft surface to lay unit down. Locate the fan on the right side of the compressor.
- On bottom side of unit, locate these two screws pictured below. Remove them to release the external fan.
- With the fan released, refer to back side of the unit. Follow the red and black wire of the fan to locate the connector fastened by a plastic wire clip. Unscrew the fastener and disconnect the fan.
- Once the fan is removed, you will notice corner brackets on one side of the fan. Remove these and place them on your new fan.
- Connect your new fan and retrace your steps backward to complete your replacement.