This applies to AB-1200, AB-1200B, AB-1200X, AB-850, AB-850B, and NBC126SS0X
Possible Causes | Solution |
No power | Verify unit is plugged into a working outlet |
The temperature setting is off | Turn to the on position |
The temperature dial is damaged (can rotate all the way around) | Replace the dial |
The dial is turned to an invalid area | Rotate the dial to the middle. If the temperature is cooling normally, adjust to desired temperature |
The light flashes | NTC1 is damaged, Replace |
Power on again after unplugging and the light comes on for about 2 seconds | NTC2 is damaged, Replace |
The compressor does not vibrate | The compressor, starter, or protector may be damaged |
The compressor is vibrating | Capillary plug or refrigerant leak |
Storing too many beverages without adequate cooling time | Allow longer cooling time |